摘要:

针对溴化锂吸收式制冷机在运行中出现的换热管泄漏、溶液污染、变频器故障等问题,结合实践经验分析了原因,并提出一些解决办法和应对措施,为化工装置冷水系统的长周期、稳定运行提供了参考经验。


关键词: 溴化锂 / 制冷机 / 泄漏 / 措施

Abstract:

In view of such problems as heat eXchange tube leakage , solution pollution and frequency converter failure in the operation of lithium bromide absorption refrigerators , the causes are analyzed based on practical eXperience and some solutions and countermeasures are put forward ,  which provide some reference for the long-termstable operation of cold water system of chemical plants.


Keywords: lithium bromide / refrigerator / leakage / measure